Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.593
Filtrar
1.
Appl Radiat Isot ; 205: 111192, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38245995

RESUMO

The counting efficiency calibration for in vivo measurement is crucial to derive the activity of radionuclides residing inside a monitored subject. Recently, virtual calibration based on computational phantoms has become popular, yet some key questions remain unresolved. Here, we focus on the in vivo measurement of Pb-210 in the skull and systematically examine how virtual calibration compares to those using physical phantoms and how the variety of computational phantoms affects the derived counting efficiency. It is found that the virtually calibrated efficiency based on the MIDA phantom, which characterizes the highest anatomical fidelity, shows reasonable consistency with the experimental counterpart, with a relative bias of approximately 10%. However, in comparison to the case based on the MIDA phantom, those based on the BOMAB and MIRD phantoms show larger deviation, demonstrating underestimations on the counting efficiency by 51% and 42%, respectively. This finding underscores the critical role of computational phantoms in the virtual calibration. This study contributes to the development of techniques for assessing lung cancer risk resulting from chronic radon exposure through in vivo measurement of skeletal Pb-210 activity.


Assuntos
Chumbo , Contagem Corporal Total , Contagem Corporal Total/métodos , Simulação por Computador , Calibragem , Método de Monte Carlo , Radioisótopos de Chumbo , Crânio , Imagens de Fantasmas
2.
Radiat Prot Dosimetry ; 200(3): 294-304, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38145953

RESUMO

The Nuclear Medicine Department of Sainte-Anne military hospital in Toulon uses 99mTc, 123I and 18F unsealed sources to provide therapeutic and diagnostic care. For a few years, only ambient air and surface monitoring were performed to check the absence of internal contamination risk for workers. To verify this risk assessment hypothesis, confirmatory monitoring programme including in vivo and in vitro measurements was performed by the French defence radiation protection service (SPRA, Clamart). Here, due to the short half-life of targeted radionuclides, the analytical sensitivity was determined with estimations of minimal detectable activities and derived recording levels. It was shown that sensitivity was sufficient to detect an internal contamination leading to an effective dose of 0.1 mSv for few days post intake. At the same time, around 20 whole-body countings were performed. Results were below minimal detectable activity and were confirmed by 24-hours urine analysis. So, actual working conditions do not lead to measurable internal contamination for nuclear medicine staff.


Assuntos
Medicina Nuclear , Exposição Ocupacional , Monitoramento de Radiação , Estados Unidos , Humanos , Doses de Radiação , Hospitais Militares , Radioisótopos/análise , Contagem Corporal Total/métodos , Exposição Ocupacional/análise , Monitoramento de Radiação/métodos
3.
J Radiol Prot ; 43(4)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37883938

RESUMO

This study aimed to develop effective methods for monitoring internal contamination among workers handling radioactive materials in various fields. A total of 160 workers from nuclear power plants, medical institutions, military units, and educational/research institutions were included in the study. The monitoring methods included urinalysis and whole-body counting (WBC) using a mobile radio bioassay laboratory (MRL). Gamma-emitting radionuclides were monitored using the MRL WBC system, and a separate pretreatment procedure was used for tritium measurement in urine samples. Gross beta-screening was performed using a liquid scintillation counting system. The results were evaluated on the basis of the established screening criteria and compared with the dose limits. Additionally, tritium concentrations in the bodies of workers in the vicinity of a heavy-water reactor was analysed to assess the association between tritium concentration and occupation. The results showed a wide distribution of tritium concentrations. Workers involved in fuel and maintenance tasks demonstrated the maximum exposure. Workers in medical facilities showed low levels of internal contamination, which was primarily related to tasks involving radioactive isotopes. Military personnel involved in equipment repair showed significant tritium contamination due to damage during repairs. Workers in educational and research institutions in general had low levels of internal contamination.


Assuntos
Monitoramento de Radiação , Humanos , Trítio , Monitoramento de Radiação/métodos , Radioisótopos/análise , Contagem Corporal Total , Centrais Nucleares
4.
Radiat Prot Dosimetry ; 199(15-16): 1848-1852, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819285

RESUMO

A new in-vivo counting system that functions as both a whole-body counter (WBC) and a lung counter (LC) was developed at the QST to enhance its dose assessment capability. This paper presents an overview of this system and the results of its performance tests. For use of the system as a WBC, three high purity germanium (HPGe) detectors installed in a 20-cm-thick iron shielding chamber are linearly arrayed over a subject lying on the bed, whereas two of the three HPGe detectors are placed over the subject's chest from side to side when using the system as an LC. The new in-vivo system was calibrated using three de-facto phantoms owned by the QST: an adult-male BOttle Manikin ABsorption (BOMAB) phantom, a Lawrence Livermore National Laboratory (LLNL) phantom and a Japan Atomic Energy Research Institute (JAERI) phantom. Monte Carlo simulations were also performed to determine an optimum location for the three detector array in the WBC mode and revealed that the peak efficiency for the BOMAB phantom (662 keV) was little varied as long as the middle detector was placed above the thorax and abdomen parts of the phantom. The calculated peak efficiencies agreed well with the observed peak efficiencies for photons with energies over 100 keV. For lung counting, a tentative Minimum Detectable Activity of 241Am was evaluated as 9.5 Bq for a counting time of 30 minutes, and a Japanese male subject with an average chest wall thinness (2.27 cm). The developed system is now ready for use.


Assuntos
Amerício , Germânio , Masculino , Humanos , Tórax , Contagem Corporal Total , Imagens de Fantasmas , Método de Monte Carlo
5.
PLoS One ; 18(7): e0288756, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37467227

RESUMO

OBJECTIVE: Hypokalemia is associated with increased risk of arrhythmias and it is recommended to monitor plasma potassium (p-K) regularly in at-risk patients with cardiovascular diseases. It is poorly understood if administration of potassium supplements and mineralocorticoid receptor antagonists (MRA) aimed at increasing p-K also increases intracellular potassium. METHODS: Adults aged≥18 years with an implantable cardioverter defibrillator (ICD) were randomized (1:1) to a control group or to an intervention that included guidance on potassium rich diets, potassium supplements, and MRA to increase p-K to target levels of 4.5-5.0 mmol/l for six months. Total-body-potassium (TBK) was measured by a Whole-Body-Counter along with p-K at baseline, after six weeks, and after six months. RESULTS: Fourteen patients (mean age: 59 years (standard deviation 14), 79% men) were included. Mean p-K was 3.8 mmol/l (0.2), and mean TBK was 1.50 g/kg (0.20) at baseline. After six-weeks, p-K had increased by 0.47 mmol/l (95%CI:0.14;0.81), p = 0.008 in the intervention group compared to controls, whereas no significant difference was found in TBK (44 mg/kg (-20;108), p = 0.17). After six-months, no significant difference was found in p-K as compared to baseline (0.16 mmol/l (-0.18;0.51), p = 0.36), but a significant increase in TBK of 82 mg/kg (16;148), p = 0.017 was found in the intervention group compared to controls. CONCLUSIONS: Increased potassium intake and MRAs increased TBK gradually and a significant increase was seen after six months. The differentially regulated p-K and TBK challenges current knowledge on potassium homeostasis and the time required before the full potential of p-K increasing treatment can be anticipated. TRIAL REGISTRATION: www.clinicaltrials.gov (NCT03833089).


Assuntos
Doenças Cardiovasculares , Hipopotassemia , Adulto , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Potássio/análise , Arritmias Cardíacas , Contagem Corporal Total
6.
Appl Radiat Isot ; 194: 110685, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36758323

RESUMO

Individual monitoring can provide an estimate of the radioactivity present in the body of the exposed individuals. Periodic monitoring of occupationally exposed individuals is of great importance in case of accidental incorporation. Computational phantoms and Monte Carlo codes are often used to complement the calibration method of counting systems in internal dosimetry. Here, counting efficiency (CE) factors for a WBC system were calculated using MC simulations. The WBC system with a NaI(Tl) detector and the BOMAB phantom was modeled using three MC codes. After validation, the models were used to obtain CE values for a wide range of energies, and a CE curve was generated for the WBC system. To estimate the effects of anatomical differences on the measurement process, two anthropomorphic voxel phantoms were modeled using the VMC code. For the detector position with the highest CE value, the differences when comparing BOMAB results with the MaMP and Yale results were (-1 ± 6)% and (-1 ± 3)%, respectively. The results confirm that the use of the BOMAB phantom is a good approach for the calibration of the whole-body counter system. Measurements should be made at detector position with the highest CE values, and it is recommended to use the mean Monte Carlo CE values calculated in this work.


Assuntos
Radiometria , Contagem Corporal Total , Humanos , Contagem Corporal Total/métodos , Simulação por Computador , Radiometria/métodos , Imagens de Fantasmas , Método de Monte Carlo
7.
Radiat Environ Biophys ; 61(3): 391-398, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35835934

RESUMO

Rod sources are a common tool for the calibration of whole-body counters in combination with the Saint-Petersburg brick phantom. Here, a method for the production of such sources in ordinary radiochemical laboratories is presented. The rod sources consist of a tubular capsule of rigid polyvinyl chloride with a radioactive filling of epoxy resin. The method allows the production of rod sources at material costs of about 1 € per rod source and of ten rod sources by one person per day. Quality-assurance measurements were performed regarding the spatial distribution of the activity within the rod sources and the distribution of the activity throughout a set of sources. The relative double standard deviation of the activities of five different segments of single rod sources was 7.1%. The relative double standard deviation within a set of 90 rod sources was 2.8% after those 11% of sources with the greatest deviation from the arithmetic mean were discarded. Tests according to ISO 2919 to certify the rod sources as sealed sources of Class 2 of this standard were successfully conducted. The bending test proved to be the most critical test for the rod sources; the sources were broken by a mass of 12-14 kg, which is only slightly more than the stipulated mass of 10.2 kg. The presented method allows for a cost- and labour-effective production of sealed radioactive rod sources and thus facilitates the application of the Saint-Petersburg brick phantom for calibrations and interlaboratory comparisons of whole-body counters.


Assuntos
Resinas Epóxi , Contagem Corporal Total , Calibragem , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Federação Russa , Contagem Corporal Total/métodos
8.
Appl Radiat Isot ; 180: 110020, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34890882

RESUMO

In-vivo whole body monitors are calibrated with various types of phantoms like Bottle Mannikin absorption phantom (BOMAB), IGOR phantom, Masonite cut sheet phantom, realistic numerical phantoms (NORMAN, ICRP voxel phantom). These phantoms contain either point sources, rod sources, uniform source or radionuclides distributed in soft tissues etc. In this study the efficiency values of Shadow Shield wholebody counter (SSC) for 137Cs and 60Co obtained theoretically using ICRP adult voxel male reference phantom (ICRP-AM) having sources distributed in soft tissues and muscles ICRP-AM(S) are compared with the measured efficiencies of Indian BOMAB phantom having mid axial source distribution (BOM-I(A)). The results show that the efficiency value of BOM-I(A) for 137Cs and 60Co is 30% and 20% lower respectively compared to that of ICRP-AM(S). This is due to the variation in size, composition and source distribution between the two phantoms. Study using Indian Voxel phantom shows that the increase in the size of ICRP-AM contributed to an increase of 14% for 137Cs. In case of 60Co the size did not have any influence. Uniform distribution has 9% and 17% higher efficiency than axial distribution for 137Cs and 60Co respectively as shown by the simulation study using uniformly filled Indian BOMAB phantom (BOM-I(U)). The actual tissue composition and source distribution in soft tissue as shown by Indian voxel has efficiencies 12-14% higher compared to BOM-I(U). The systemic error due to the axial source distribution is recognized and quantified to be 22-25% lower compared to that of a realistic phantom with radionuclides in soft tissue and muscle. This study has resulted in an efficiency of the system using Indian realistic Voxel phantom. The efficiencies are 0.65 CPS/kBq for 137Cs and 0.49 CPS/kBq for 60Co.


Assuntos
Imagens de Fantasmas , Contagem Corporal Total/instrumentação , Adulto , Calibragem , Desenho de Equipamento , Humanos , Índia , Masculino , Método de Monte Carlo
9.
Acta Radiol ; 63(1): 11-21, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33356358

RESUMO

BACKGROUND: The radiation dose to staff performing endoscopic retrograde cholangiopancreatography (ERCP) is not negligible. PURPOSE: To evaluate the shielding effect of a table-suspended lower-body radiation shield for the positions in the room occupied by the operator, assisting nurse, and anesthesiologist, used during ERCP procedures with a mobile C-arm. MATERIAL AND METHODS: Eye lens dose, whole body dose, and extremity dose were measured with and without a table-suspended lower-body radiation shield in a phantom model and in clinical routine work. The effect of the shield was evaluated for each scenario and compared, and a projection was made for when shielding should be required from a regulatory point of view. RESULTS: In the phantom measurements, the shield provided significant shielding effects on the body and lower extremities for the operator but no significant shielding of the eye lens. The shielding effect for the assisting nurse was limited to the lower extremity. The clinical measurements yielded the same general result as the phantom measurements, with the major difference that the shield provided no significant reduction in the whole-body dose to the operator. CONCLUSION: The table-suspended shield has a significant shielding effect for the lower extremities of the operator and assisting nurse. For annual dose-area product values >300,000 cGycm2, the protection of the operator should be reinforced with a ceiling-suspended shield to avoid doses to the eye lens and body in excess of regulatory dose restrictions.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/métodos , Desenho de Equipamento , Humanos , Cristalino/efeitos da radiação , Extremidade Inferior/efeitos da radiação , Imagens de Fantasmas , Doses de Radiação , Suécia , Contagem Corporal Total
10.
Probl Radiac Med Radiobiol ; 26: 124-140, 2021 Dec.
Artigo em Inglês, Ucraniano | MEDLINE | ID: mdl-34965545

RESUMO

OBJECTIVE: The key factors identification in radiation dose formation in population of radiologically contaminatedareas of Rivne oblast in the current period of accident through comprehensive radiation and hygienic monitoring inreference settlements in 2020 and estimation of their impact on dose formation were the study objectives. MATERIALS AND METHODS: Comprehensive radiation and hygienic monitoring of settlements in Rivne oblast(province) was provided in Stare Selo, Vezhytsia, Perekhodychi, and Drozdyn villages of Rokytne district, where thehighest radiation doses were registered after the ChNPP accident. Studies were conducted in September 2020.Measurements (n=696, 318 adults, and 378 children) were performed using the whole body counters (WBC) to deter-mine the internal radiation doses. The 48 samples of milk, 45 samples of potatoes and vegetables, and 35 samplesof wild products were collected in local farms and measured for the 137Cs and 90Sr content. Residents of the studiedsettlements (n=229, 140 adults, and 89 children) were interviewed about the levels of consumption of staple food-stuffs. External radiation doses were evaluated in all the studied settlements. Mathematical, dosimetric, and radio-chemical methods were applied. RESULTS AND CONCLUSIONS: Annual effective radiation doses of the Rivne oblast population in 2020 were formedmainly due to internal radiation ones that not exceeded 1.24 mSv · year-1 in adults and 0.65 mSv · year-1 in childrenagainst the RCT criterion of 1 mSv · year-1. Further 1.2-1.9-fold decrease in the annual internal radiation doses vs.the results of WBC-monitoring in autumn of 2017 was registered in the surveyed settlements. The latter confirmeda time pattern of radiation levels gradual reduction at the current stage of Chornobyl accident since 2011. Intakeof 137Cs with milk and wild mushrooms, which traditionally occupy a significant part of diet in the Rivne Polissya areaand have consistently high levels of radioactive cesium contamination, remains a key factor of internal radiationdose forming in residents of the surveyed settlements of Rivne oblast.


Assuntos
Radioisótopos de Césio , Acidente Nuclear de Chernobyl , Relação Dose-Resposta à Radiação , Exposição Ambiental/estatística & dados numéricos , Exposição à Radiação/estatística & dados numéricos , Monitoramento de Radiação/estatística & dados numéricos , Contagem Corporal Total , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Césio/análise , Criança , Pré-Escolar , Exposição Ambiental/efeitos adversos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Exposição à Radiação/efeitos adversos , Liberação Nociva de Radioativos/estatística & dados numéricos , Medição de Risco/estatística & dados numéricos , População Rural/estatística & dados numéricos , Ucrânia , Adulto Jovem
11.
Probl Radiac Med Radiobiol ; 26: 199-218, 2021 Dec.
Artigo em Inglês, Ucraniano | MEDLINE | ID: mdl-34965549

RESUMO

Objective of research is to improve the electronic database of WBC measurements dated 1986 by inputting of newinformation from paper carriers, reconstruction of information gaps, verification and analysis of new entered data,revision of internal exposure doses that are based on results of WBC measurements dated 1986. MATERIALS AND METHODS: In 2013-2015 during a revision of databases (DB) of WBC measurements results dated1986-2014, it was discovered a great amount of paper carriers with information about WBC measurements, includ-ing the ones dated 1986, that were not inputted to the electronic DB. The paper carriers were systematized andordered by the following indicators: place of residence of a person and place of WBC measurement, institution andoperator that made the measurement, measurement device and date of measurement. For a comfortable inputtingof the information to the electronic DB, it was additionally created a form which exists as an option in existing program complex Silbody (Version 19.0.9). In the revised DB of WBC measurements dated 1986 internal exposure dosesfrom radio-cesium of Chornobyl origin were computed based on an ecological and dosimetric model for radio-cesiummigration in environment and a model for radio-cesium metabolism in human body. In the work, mathematical andstatistical methods of research were used. RESULTS: In 2019-2021 additionally 35,319 notes were inputted to the electronic DB of WBC measurement dated1986, and as a result its volume increased in 2.2 times. Mostly those are data on results concerning residents of Kyiv,Zhytomyr, Donetsk, Cherkasy, Odessa, Ivano-Frankivsk, and Rivne Oblasts. It was established the information onmeasurement devices and respectively on the minimal detected activity (MDA) for 27,119 notes (76.7 % of all newentered). Information is reconstructed about the body mass of all persons under investigation. Evaluation is madefor values of intake of incorporated radionuclides 137Cs and 134Cs for all new entered to DB. Quality of reconstructedinformation was analyzed. To group 1, «qualitative¼, it was classified 18,598 notes (53 % of all new entered), measurements in 1986 (including new entered). Dose not exceeding 1 mSv was obtained by 80 % of adults (older than20), as well as 73 % of persons younger than 20. CONCLUSION: To DB of WBC measurements, it was additionally inputted 35,319 notes on results of measurementsdated 1986. New entered information is verified and distributed by the quality groups. Individual exposure dosesevaluated based on those data can be used for further scientific research.


Assuntos
Acidente Nuclear de Chernobyl , Bases de Dados Factuais/estatística & dados numéricos , Bases de Dados Factuais/tendências , Exposição à Radiação/estatística & dados numéricos , Monitoramento de Radiação/estatística & dados numéricos , Radiometria/estatística & dados numéricos , Contagem Corporal Total/estatística & dados numéricos , Confiabilidade dos Dados , Coleta de Dados/estatística & dados numéricos , Coleta de Dados/tendências , Monitoramento Epidemiológico , Previsões , Humanos , Sistema de Registros , Ucrânia
12.
Radiat Environ Biophys ; 60(4): 681-684, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34455474

RESUMO

A computer code called Virtual Igor is presented. The code generates an analytical representation of the Saint Petersburg brick phantom family (Igor, Olga, Irina), which is frequently used for the calibration of whole-body counters, in arbitrary user-defined layouts for the use in the Monte-Carlo radiation transport code MCNP. The computer code reads a file in the ldraw format, which can easily be produced by simple freeware software with graphical user interfaces and which contains the types and coordinates of the bricks. Ldraw files with the canonical layouts of the brick phantom are provided with Virtual Igor. The code determines the positions of (2.75 cm)3 segments of the bricks, where 2.75 cm is the smallest length in the layout and, therefore, represents the spacing of the segment lattice. Each segment contains the exact geometry of the respective part of the brick, using cuboid and cylindrical surfaces. The user can define which rod source drill holes of which bricks contain the rod-type radionuclide sources. The method facilitates the comparison of different layouts of the Saint Petersburg brick phantom with each other and with anthropomorphic computational phantoms.


Assuntos
Contagem Corporal Total , Simulação por Computador , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Federação Russa
13.
Health Phys ; 121(6): 607-612, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34411055

RESUMO

ABSTRACT: Testing the decision level (DL) and minimum detectable amount (MDA) of a radionuclide for a direct bioassay (in vivo) counting system is a requirement for in vivo monitoring programs across the DOE complex. Bottle manikin absorption (BOMAB) and torso phantoms are used in conjunction with point sources to facilitate the testing. This paper describes a method of testing the DL and MDA values of in vivo counting systems with equipment commonly used by in vivo programs. This method is cost effective and minimizes waste since the radiological sources used can have broad ranges for decay activities. The results from the testing indicated that the current DL and MDA values are valid for the equipment and methods used at the Hanford in vivo counting facility.


Assuntos
Radioisótopos , Contagem Corporal Total , Método de Monte Carlo , Imagens de Fantasmas , Contagem Corporal Total/métodos
14.
Nucl Med Commun ; 42(11): 1285-1287, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34100797

RESUMO

BACKGROUND: There are many protocol variations in the whole-body 75SeHCAT retention test [whole-body retention (WBR)] for investigation of bile acid diarrhoea. The time between capsule consumption and first count, however, is widely taken, without debate, to be 3 h. In the Covid-19 era, it is desirable to limit the time patients spend in the department. We, therefore, questioned the need for a 3 h interval between capsule administration and the initial count. METHODS: Using an uncollimated gamma camera, whole-body counting was performed at 5, 30 and 180 min after capsule ingestion in 24 patients with chronic diarrhoea. Geometric mean was taken of counts acquired from posterior and anterior projections. WBR was expressed as the ratio of 7 day-to-initial whole-body counts (%) to give WBR5, WBR30 and WBR180. A small meal was given at 60 min after capsule ingestion. RESULTS: There was a close correlation between WBR30 and WBR180 (y = 1.0x - 0.29%; r = 0.99). For WBR180 values of <15% (lower limit of normal), there was close agreement between WBR30 and WBR180 (bias 0.03%; precision 0.7%). WBR5 overestimated WBR180. However, cWBR5, obtained by multiplication of WBR5 by 0.75, also correlated closely with WBR180 (y = 1.2x - 4.5%; r = 0.97), and there was close agreement between cWBR5 and WBR180 for WBR180 values <15% (bias 0.08%, precision 1.3%). CONCLUSION: The first whole-body count in the 75SeHCAT test can be undertaken at 30 min postcapsule without loss of accuracy, or even 5 min if only subnormal values are considered relevant. No food is required after capsule consumption.


Assuntos
Diarreia/diagnóstico por imagem , Diarreia/metabolismo , Contagem Corporal Total , Adulto , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia
15.
Health Phys ; 121(2): 133-149, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34028388

RESUMO

ABSTRACT: More than 9 y have passed since the 2011 nuclear disaster in Fukushima Prefecture, Japan. During this period, much effort has been spent on the dose reconstruction for Fukushima residents; however, the estimation of the internal dose due to the potential intake of the short-lived radionuclides (mainly iodine-131) has been challenging because of the lack of direct human measurements at the early phase of the accident. Our previous study revealed that the residual cesium body contents observed in delayed whole-body counter (WBC) measurements of residents from Namie-town, one of the most affected municipalities, varied greatly with the timepoint of their evacuations on 12 March 2011 when the first explosive event occurred at the accident site; i.e., the late evacuees had much higher residual cesium body contents compared to the prompt evacuees. The present study thus aimed to clarify this finding by reproducing the exposure situation based on the evacuees' personal behavioral data in combination with the latest atmospheric transport and dispersion model (ATDM) simulation for 356 selected subjects in adult and 15-y (13-17 y) age groups. The results demonstrated that the ATDM simulation-based method could reasonably reproduce the subjects' exposure situation, supporting the previous finding. However, the residual cesium-137 body contents calculated by this method were only 10%-20% of those in the subjects' WBC measurements. This large discrepancy was considered to be caused by both the present method's underestimation and the overestimation of the subjects' early intake in the WBC measurements due to a conservative intake scenario not assuming potential additional intake. Additional studies are needed to further clarify the reasons for the discrepancy and to evaluate the magnitude of the inhalation dose in the accident.


Assuntos
Acidente Nuclear de Fukushima , Monitoramento de Radiação , Adulto , Radioisótopos de Césio/análise , Humanos , Japão , Centrais Nucleares , Monitoramento de Radiação/métodos , Contagem Corporal Total
16.
Radiat Prot Dosimetry ; 194(2-3): 65-75, 2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34027550

RESUMO

The authors' previous study suggested that a simple standing-type whole-body counter called FASTSCAN (Canberra, Meriden, CT, USA), widely installed throughout Japan after the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in March 2011, could be used for thyroid measurements in internal dose assessment after a future radiological incident accompanied by the release of 131I into the environment. The present study performed Monte-Carlo simulations using a computational human phantom with several patterns of body surface contamination and used the results to formulate a method for probabilistic analyses of 131I thyroid activity in persons with surface contamination. The major advantage of this method is that the upper limit of the thyroid activity can be determined from the relative frequency distribution without identifying where body surface contamination remains. Therefore, this method is especially effective for use in the early phase of a radiological incident when time and resources are limited, making it difficult to physically remove all body surface contamination for the purpose of gaining more accurate population-wide thyroid screening measurements. As a case study of the FDNPP accident, the proposed method was applied to the results of in vivo measurements for a male subject with body surface contamination. In comparing the probabilistic analyses before and after removal of the subject's contaminated work clothes, the uncertainty of the relative frequency distribution of 131I thyroid activity was reduced by their removal. Therefore, in terms of accurate estimates and avoidance of radiation exposure from their contaminated clothes, efforts to remove body surface contamination still should be made as much as possible in the chaotic situation of the early phase of a radiological incident.


Assuntos
Acidente Nuclear de Fukushima , Monitoramento de Radiação , Humanos , Radioisótopos do Iodo/análise , Japão , Masculino , Glândula Tireoide/diagnóstico por imagem , Contagem Corporal Total
17.
Health Phys ; 120(4): 387-399, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33229943

RESUMO

ABSTRACT: It is very important to determine the precise internal thyroid doses of Fukushima residents involved in the 2011 Fukushima nuclear disaster, particularly for small children. This has been challenging due to the lack of direct human measurements to identify 131I, the biggest contributor to the thyroid doses. We previously used a dataset of late whole-body counter (WBC) measurements targeting 134Cs and 137Cs for the thyroid dose estimation in comparison with the intake ratios of 131I to 137Cs (or 134Cs) derived from thyroid and whole-body doses individually obtained from different subject groups, assuming simultaneous acute intake via inhalation. Herein, we applied the same method to the doses of residents in Iwaki city (located south of the Fukushima Daiichi Nuclear Power Plant) with a relatively high activity ratio (131I/137Cs) for the ground deposition density. Our analyses revealed that the intake ratio (131I/137Cs) for the Iwaki residents was 4.2-4.3, which is relatively consistent with the values obtained in other studies (average 3.0-5.0). No regional difference in the intake ratios from other areas was observed, but further studies are required to determine the accurate intake ratio in the early phase of the accident, in particular focusing on the reasonable interpretation of results of the late WBC measurements to evaluate the actual Cs intake.


Assuntos
Acidente Nuclear de Fukushima , Monitoramento de Radiação , Radioisótopos de Césio/análise , Criança , Humanos , Radioisótopos do Iodo/análise , Japão , Doses de Radiação , Monitoramento de Radiação/métodos , Glândula Tireoide , Contagem Corporal Total/métodos
18.
Regul Toxicol Pharmacol ; 119: 104835, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33227363

RESUMO

Quantitative whole-body autoradiography (QWBA) is largely used to evaluate tissue distribution of small molecule drugs. In QWBA, radioactivity is measured as the intensity obtained from the autoradiogram. It is known that lower intensity per a region of interest (ROI) or smaller size of ROI increases the variability of intensity. In fact, as some tissues are very small (e.g., the choroidea), ensuring reliability on the intensity for measuring radioactivity in these tissues is difficult in case of under- or over-estimation of radioactivity concentration owing to their variation of low radioactivity intensity of ROI. We thus analyzed the relationships between the size, intensity, and precision of ROI to determine the statistically significant lower limit of quantification (LLOQ) in very small tissues. To investigate the difference in correlation between the radiation source (commercial planar radiation standard [com-ST] and self-made radiation standard [self-ST] consisting of radioactive compounds and matrices), apparatus, or setting environment of the apparatus, correlation analysis was conducted under various conditions. Our results revealed that LLOQ can be calculated by simply using the correlation equation because a common relationship was observed between self-ST, which is used in QWBA, and com-ST. This methodology was thus considered valuable for ensuring LLOQ determination in QWBA.


Assuntos
Autorradiografia/métodos , Radioisótopos de Carbono/análise , Limite de Detecção , Doses de Radiação , Radioatividade , Contagem Corporal Total
19.
Probl Radiac Med Radiobiol ; 25: 177-187, 2020 Dec.
Artigo em Inglês, Ucraniano | MEDLINE | ID: mdl-33361834

RESUMO

OBJECTIVE: of this study was to determine the levels of radionuclides in the rescuers' bodies of the SES during firefighting in the exclusion zone of the Chornobyl nuclear power plant and to assess the dose of internal radiation dueto this receipt. MATERIALS AND METHODS: From 06.04.2020 to 19.05.2020 in the State Institution «National Research Center forRadiation Medicine of the National Academy of Medical Sciences of Ukraine¼ (NRCRM) measurements of the contentof incorporated gamma radionuclides on whole body counters (WBC) operational class «Screener-3M¼ (Minimumdetected activity (MDA) is 300-500 Bq for 5 minutes of measurement at 137Cs) and expert high-sensitivity WBC (MDAis 20 Bq for 10 minutes of measurement at 137Cs). 470 people (523 measurements) in three groups of personnel ofthe SES of Ukraine who took part in the forest fire liquidation in the exclusion zone in the period from April 4 toMay 5, 2020 were examined. Mathematical and spectrometric methods are used in the work. RESULTS AND CONCLUSIONS: In the vast majority (95 %) of the personnel of the SES of Ukraine, examined at the WBCoperational class «Screener-3M¼ (more than 500 measurements), the assessment of the values of the individualeffective dose of internal radiation due to 137Cs in the body during firefighting, assuming that it receipt occurredduring operation in the exclusion zone, did not exceed the minimum dose detected by MDD (5-14 µSv). The average value of the effective dose of internal radiation in the group of personnel of the State Emergency Service ofUkraine in Kyiv, which participated in the elimination of forest fires in the exclusion zone from April 4 to May 5, 2020(26 people) studied at the expert WBC, is 2.5 ± 1.1 µSv, in the group of personnel of the SES of Ukraine in Cherkasyregion, which participated in the fire on April 19-24, 2020 (9 people) - 2.2 ± 0.6 µSv, in the group of personnel ofthe SES of Ukraine in the Kyiv region, which took part in the elimination of the forest fire in the exclusion zone onApril 4 - May 5, 2020 (42 people) - 4.4 ± 2.4 µSv. Maximum values of 5.1 µSv, 3.5 µSv, 11.8 µSv in the groups ofKyiv city, Cherkasy and Kyiv regions, respectively, which is much lower than the basic dose limit for the populationfrom man-made sources of 1000 µSv · year-1 according to the Law of Ukraine about protection of the person againstinfluence of ionizing radiation.


Assuntos
Acidente Nuclear de Chernobyl , Socorristas , Exposição à Radiação/efeitos adversos , Lesões por Radiação/patologia , Carga Corporal (Radioterapia) , Radioisótopos de Césio/análise , Relação Dose-Resposta à Radiação , Raios gama/efeitos adversos , Humanos , Doses de Radiação , Lesões por Radiação/epidemiologia , Lesões por Radiação/etiologia , Radiometria/métodos , Fatores de Tempo , Ucrânia/epidemiologia , Contagem Corporal Total
20.
Probl Radiac Med Radiobiol ; 25: 188-203, 2020 Dec.
Artigo em Inglês, Ucraniano | MEDLINE | ID: mdl-33361835

RESUMO

OBJECTIVE: to identificate the main factors and assess their impact on the formation of radiation doses to the population of radioactively contaminated areas of Kyiv region at the current stage of the accident based on complexradiation and hygienic monitoring in the reference settlements in 2019. MATERIALS AND METHODS: Comprehensive radiological and hygienic monitoring was carried out in eight settlementsof Kyiv region - villages of Ragivka, Lygovyky, Mar'yanivka, Zelena Poliana of Polis'kyi district and villages ofHornostaipil, Dytiatky , Pisky, Karpylivka of Ivankiv district. The content of incorporated 137Cs was determined withdirect measurement on whole body counters (WBC) samples of basic foodstuffs were collected to determine the content of radionuclides 90Sr and 137Cs, residents were interviewed about the levels of consumption of these products,and work was performed to estimate external radiation doses. Mathematical, dosimetric, radiochemical methods areused in the work. RESULTS: There was a further decrease in annual doses of internal radiation in the surveyed settlements in 1.3 times, bothin Polis'kyi district (0.041 mSv · year-1 in 2016, 0.030 mSv · year-1 in 2019) and in Ivankiv district (0.023 mSv · year-1in 2016, 0.018 mSv · year-1 in 2019). It is possible to state a slowdown in the reduction of radiation doses comparedto previous years: from 2010 to 2013, the annual doses of internal radiation in the surveyed settlements decreasedby 1.8-2.4 times, from 2013 to 2016 - by 2.3-3.6 times. The content of 137Cs and 90Sr in milk and potatoes in theinspected settlements is lower than the permissible level of the Hygienic Standard HS 6.6.1.1-130-2006 and the useof these foods can not significantly affect the formation of the internal radiation dose. The content of 90Sr in milksamples in the settlements of Ivankiv district is in the range of 2.1-9.9 Bq · kg-1 (in 2016: 1.3-7.4 Bq · kg-1), whichdoes not exceed the permissible level of 20 Bq · kg-1, but due to the dynamics needs further monitoring. The content of 137Cs in samples of dried mushrooms collected from residents of Kyiv region in 2019, as in previous years, issignificantly (up to 100 times) higher than permissible level, and has a high uncertainty - from 1.4 kBq · kg-1 to223.7 kBq · kg-1. CONCLUSIONS: It is established that the annual effective radiation doses of the population in the surveyed settlements in the current year are formed due to internal radiation doses that do not exceed 0.46 mSv · year-1 in Ivankivdistrict and 0.51 mSv · year-1 in Polis'kyi district, which below the RCT criterion 1 mSv · year-1. The main factor that forms the dose of internal radiation of the residents of the surveyed state of emergency of Kyiv region is the intake of 137Cs in the body with forest products, primarily mushrooms.


Assuntos
Acidente Nuclear de Chernobyl , Contaminação Radioativa de Alimentos/análise , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Carga Corporal (Radioterapia) , Radioisótopos de Césio/análise , Humanos , Doses de Radiação , Radiação Ionizante , População Rural , Radioisótopos de Estrôncio/análise , Ucrânia , Contagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...